Auditory Evoked Potential - At its best!
The ICS Chartr EP 200 builds on the expertise of our ICS Chartr line. Creating smaller, portable systems while maintaining the easy-to-use software interface valued by our customers. New features maintain the user friendliness and assist you in performing any AEP test with ease.
Comprehensive test battery
ICS Chartr EP 200 provides a comprehensive test battery for diagnosing a wide range of auditory and vestibular disorders. Users can create their own protocols or get an immediate start with the pre-loaded ones.
ICS Chartr EP 200 provides a comprehensive test battery for diagnosing a wide range of auditory and vestibular disorders. Users can create their own protocols or get an immediate start with the pre-loaded ones.
Easy navigation
The software interface ensures a smooth work process. Three easy access tabs make acquiring and reviewing data quick and intuitive. The New Test tab gives direct access to test protocols, the Quick Settings tab gives easy access to protocol parameters and the Review tab gives instant access to all saved data.
The software interface ensures a smooth work process. Three easy access tabs make acquiring and reviewing data quick and intuitive. The New Test tab gives direct access to test protocols, the Quick Settings tab gives easy access to protocol parameters and the Review tab gives instant access to all saved data.
ICS Chartr EP 200 at a glance:
• Click Evoked ABR
• Toneburst ABR
• Electrocochleography
• Auditory Middle Latency Response (AMLR)
• Auditory Late Response (ALR)
• P300 - optional
• Vestibular Evoked Myogenic Potential (VEMP) - optional
• Auditory Steady State Response (ASSR) - optional
• Click Evoked ABR
• Toneburst ABR
• Electrocochleography
• Auditory Middle Latency Response (AMLR)
• Auditory Late Response (ALR)
• P300 - optional
• Vestibular Evoked Myogenic Potential (VEMP) - optional
• Auditory Steady State Response (ASSR) - optional
Improve patient care with VEMP
The ICS Chartr EP 200 comes with an optional VEMP module for a more comprehensive vestibular assessment. The VEMP module utilizes EMG monitoring with a unique device that eases the testing procedure and allows users to test with confidence.
Readily accessible VEMP protocols
A list of VEMP protocols are added under the New Test tab already known from the EP interface. Available protocols include: toneburst and click air conduction VEMP protocols, bone conduction VEMP protocol and OVEMP protocol. Users can also create their own.
A list of VEMP protocols are added under the New Test tab already known from the EP interface. Available protocols include: toneburst and click air conduction VEMP protocols, bone conduction VEMP protocol and OVEMP protocol. Users can also create their own.
Instant EMG monitoring
“The tonic state of the SCM muscle is a critical parameter in the recording method of the VEMP. Thus, controlling the level of tonic EMG would appear to be a prerequisite for the accurate interpretation of the VEMP”(1).
“The tonic state of the SCM muscle is a critical parameter in the recording method of the VEMP. Thus, controlling the level of tonic EMG would appear to be a prerequisite for the accurate interpretation of the VEMP”(1).
The ICS Chartr 200 VEMP monitor records the EMG level and thus makes VEMP testing a lot easier. The monitor assists in controlling the amount of tonic level EMG by making the patient and tester aware of the level through a series of lights. The monitor can be easily mounted or held by the patient during data collection.
Efficient Multi-frequency ASSR
The optional Auditory Steady State Response (ASSR) module is a great addition to the ICS Chartr EP 200, which allows you to obtain frequency specific, auditory data, quickly and efficiently.
RapidASSR™ algorithm
The RapidASSR™ response detection algorithm makes it possible to collect up 12 frequencies simultaneously (6 frequencies per ear). The proven algorithm uses a Fourier Linear Combiner with an adaptive filter and circular T2 statistical analysis*.
The RapidASSR™ response detection algorithm makes it possible to collect up 12 frequencies simultaneously (6 frequencies per ear). The proven algorithm uses a Fourier Linear Combiner with an adaptive filter and circular T2 statistical analysis*.
Instant monitoring of EEG and impedance values
The EEG is always viewable during data collection, making it easy to check the patient’s state. Impedance can be checked at any time during testing without interfering with data collection. Both timesaving features, ensuring that accurate data are collected.
The EEG is always viewable during data collection, making it easy to check the patient’s state. Impedance can be checked at any time during testing without interfering with data collection. Both timesaving features, ensuring that accurate data are collected.
Technical specifications:
Acquisition Options
Sweep Time: 5.0 – 9000 msec
Rate: 0.2 to 180/sec
A/D Resolution: 16-bit
Artifact Rejection: 99% full scale (adjustable)
Points per Trace: 600
Rate: 0.2 to 180/sec
A/D Resolution: 16-bit
Artifact Rejection: 99% full scale (adjustable)
Points per Trace: 600
Channel Options
Channels: 2 channels with optional 3rd channel for VEMP
Monitoring
Gain: 1k, 1.5k, 2k, 2.5k, 3k, 5k, 7.5k, 10k, 15k, 20k, 25k, 30k, 50k, 75k, 100k, 150k, 200k, 250k, 300k, 500k
High Pass Filter (Hz): 0.2, 0.3, 0.5, 1, 1.5, 2, 5, 10, 20, 30, 50, 100, 150, 200, 500, 1000
Low Pass Filter (Hz): 15, 30, 50, 75, 100, 150, 250, 300, 500, 600, 1k, 1.5k, 2k, 3k, 5k, 10k
Notch Filter: 50 or 60 Hz set by the manufacturer
High Pass Filter (Hz): 0.2, 0.3, 0.5, 1, 1.5, 2, 5, 10, 20, 30, 50, 100, 150, 200, 500, 1000
Low Pass Filter (Hz): 15, 30, 50, 75, 100, 150, 250, 300, 500, 600, 1k, 1.5k, 2k, 3k, 5k, 10k
Notch Filter: 50 or 60 Hz set by the manufacturer
Stimulus Options
Transducer: Headphones, Insert Earphones (automatic 0.8msec delay correction), Bone Oscillator (B71)
Stimulus Type: Click & toneburst
Masking: White noise
Click Duration: 100 usec
Toneburst Freq (Hz): 125, 250, 500, 1k, 1.5k, 2k, 3k, 4k, 6k, 8k
Toneburst Ramp/Plateau: User defined (cycles)
Toneburst Envelope: Linear, Hanning, Blackman, Gaussian
Intensity: 132 dB pe SPL; user definable nHL
Polarity: Rarefaction, condensation, alternating
Calibration Reference: Calibration table in dB SPL with a user definable normal hearing threshold table in nHL
Stimulus Type: Click & toneburst
Masking: White noise
Click Duration: 100 usec
Toneburst Freq (Hz): 125, 250, 500, 1k, 1.5k, 2k, 3k, 4k, 6k, 8k
Toneburst Ramp/Plateau: User defined (cycles)
Toneburst Envelope: Linear, Hanning, Blackman, Gaussian
Intensity: 132 dB pe SPL; user definable nHL
Polarity: Rarefaction, condensation, alternating
Calibration Reference: Calibration table in dB SPL with a user definable normal hearing threshold table in nHL
VEMP Monitor
Channel: Monitor 1 channel (left or right side)
VEMP EMG Level: User defined minimum and maximum acceptable level
VEMP EMG Level: User defined minimum and maximum acceptable level
Chartr EP 200 Dimensions/Weight
Chartr EP 200 main unit: 4.9cm x 34.2cm x 28.7cm (2” x 13.6” x 11.3”) – 2.7kg (5 lbs 7oz)
Chartr EP 200 Preamp: 3cm x 9.9cm x 16.4cm (1.19” x 3.88” x 6.44”) – .27kg (9.5oz)
Chartr VEMP Monitor: 2.9cm x 6.2cm x 9.5cm (1.13” x 2.44” x 3.75”) – 2.0kg (4.5oz)
Interface: USB to PC
Power Supply: 15V DC/2A
Safety: Chartr EP 200 was designed to meet these standards EN 60601-1, Class II, Type BF, IPXO; UL 2601-1; CAN/CSA-C22.2 No 601.1-90
Chartr EP 200 Preamp: 3cm x 9.9cm x 16.4cm (1.19” x 3.88” x 6.44”) – .27kg (9.5oz)
Chartr VEMP Monitor: 2.9cm x 6.2cm x 9.5cm (1.13” x 2.44” x 3.75”) – 2.0kg (4.5oz)
Interface: USB to PC
Power Supply: 15V DC/2A
Safety: Chartr EP 200 was designed to meet these standards EN 60601-1, Class II, Type BF, IPXO; UL 2601-1; CAN/CSA-C22.2 No 601.1-90
Computer Minimum Requirements
Processor: Pentium M or Pentium 4
RAM: Minimum 512 MB available RAM
Bus Support: USB 2.0
OS: Microsoft XP Professional - Service Pack 2 or Vista Business
CD Drive: CD-R/W
Display Resolution: Minimum screen resolution of 1024 (horiz) x 768 (vert) at 96 dpi. At Large size (120 dpi) setting, minimum resolution is 1280 (horiz) x 960 (vert)
Display Color: 32 bit color.
RAM: Minimum 512 MB available RAM
Bus Support: USB 2.0
OS: Microsoft XP Professional - Service Pack 2 or Vista Business
CD Drive: CD-R/W
Display Resolution: Minimum screen resolution of 1024 (horiz) x 768 (vert) at 96 dpi. At Large size (120 dpi) setting, minimum resolution is 1280 (horiz) x 960 (vert)
Display Color: 32 bit color.
ASSR
Number of channels: 1
Stimuli: 250, 500, 1000, 2000, 4000, 8000 Hz (up to 6 per ear) presented monaurally or binaurally
Threshold search/ 0 - 120 dB HL (insert phones), 0 - 110 dB HL (headphones)
upper lower limit: 0 - 60 dB HL (bone oscillator), 5 dB steps
Masking: White noise up to 100 dB HL
AM/FM Modulation: 20 to 105 Hz(1 Hz per step); AM depth - 0 to 100% (5% per step); FM depth - 0 to 25% (5% per step)
Gain: 1k, 2k, 3k, 5k, 10k, 20k, 30k, 50k, 100k, 200k, 300k, 500k
High Pass/Low Pass Filter: Exclusive Chartr narrow filters for RapidASSRTM
EEG: Online display during data collection or when collection is paused
Search Options: Quick Search or Straight Descent
Electrode Montage: Cz to Nape or Cz to Linked Mastoids
Test Protocols: Test protocols included for sleeping and awake patients. Protocols can be created and customized
Stimuli: 250, 500, 1000, 2000, 4000, 8000 Hz (up to 6 per ear) presented monaurally or binaurally
Threshold search/ 0 - 120 dB HL (insert phones), 0 - 110 dB HL (headphones)
upper lower limit: 0 - 60 dB HL (bone oscillator), 5 dB steps
Masking: White noise up to 100 dB HL
AM/FM Modulation: 20 to 105 Hz(1 Hz per step); AM depth - 0 to 100% (5% per step); FM depth - 0 to 25% (5% per step)
Gain: 1k, 2k, 3k, 5k, 10k, 20k, 30k, 50k, 100k, 200k, 300k, 500k
High Pass/Low Pass Filter: Exclusive Chartr narrow filters for RapidASSRTM
EEG: Online display during data collection or when collection is paused
Search Options: Quick Search or Straight Descent
Electrode Montage: Cz to Nape or Cz to Linked Mastoids
Test Protocols: Test protocols included for sleeping and awake patients. Protocols can be created and customized